{"product_id":"trimpac®-brass-monitored-fire-sprinkler-control-trim-case-assembly","title":"Trimpac® Brass Monitored Fire Sprinkler Control Trim Case Assembly","description":"\u003cdiv\u003e\n\u003cp\u003eThe Viking Trimpac® Brass Monitored Fire Sprinkler Control Trim Case Assembly provides a factory-assembled, centralized control solution for commercial and industrial fire suppression systems. Installed within deluge, wet, or multi-cycle, single interlock, and double interlock preaction assemblies, this unit integrates all necessary control and monitoring components into a compact cabinet to streamline installation and reduce field labor errors.\u003c\/p\u003e \u003cp\u003eEngineered to satisfy stringent commercial life safety mandates, this monitored assembly delivers continuous system status oversight to ensure full operational readiness. Design and testing parameters comply with applicable NFPA standards for fire protection system installation, inspection, testing, and maintenance, ensuring your infrastructure remains fully compliant with the Authority Having Jurisdiction (AHJ).\u003c\/p\u003e \u003cul\u003e \u003cli\u003e\n\u003cb\u003eFactory-Assembled Cabinet:\u003c\/b\u003e Integrates critical control components into a centralized enclosure to reduce installation time and job-site labor costs.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eDurable Brass Construction:\u003c\/b\u003e Engineered from premium brass materials to deliver exceptional corrosion resistance in demanding commercial environments.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eMonitored Configuration:\u003c\/b\u003e Provides continuous system status feedback to ensure infrastructure remains operational and compliant with life safety requirements.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eVersatile System Integration:\u003c\/b\u003e Compatible with deluge, wet, and various preaction configurations including single interlock, double interlock, and multi-cycle applications.\u003c\/li\u003e \u003cli\u003e\n\u003cb\u003eSimplified Maintenance:\u003c\/b\u003e Centralizes the control interface to streamline routine system testing and ongoing maintenance procedures.\u003c\/li\u003e\n\u003c\/ul\u003e \u003ctable\u003e \u003cthead\u003e \u003ctr\u003e \u003cth\u003e\u003cstrong\u003eTechnical Specification\u003c\/strong\u003e\u003c\/th\u003e \u003cth\u003e\u003cstrong\u003eProduct Detail\u003c\/strong\u003e\u003c\/th\u003e \u003c\/tr\u003e \u003c\/thead\u003e \u003ctbody\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eManufacturer \/ Brand\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eViking\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eModel \/ Series Number\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eTrimpac® (Includes Models D-1B, D-2B, E-2, E-3B)\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eConnection \/ Thread Size \u0026amp; Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003ePressure Rating (WWP)\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eK-Factor\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eTemperature Rating \/ Response Type\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eMaterial \/ Body Construction\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eBrass\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eAgency Listings \u0026amp; Approvals\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eN\/A\u003c\/td\u003e \u003c\/tr\u003e \u003ctr\u003e \u003ctd\u003e\u003cstrong\u003eApplicable NFPA Standards\u003c\/strong\u003e\u003c\/td\u003e \u003ctd\u003eNFPA 13 \/ NFPA 25 (Applicable to Fire Suppression and System Maintenance)\u003c\/td\u003e \u003c\/tr\u003e \u003c\/tbody\u003e\n\u003c\/table\u003e \u003cp\u003eVerify all local AHJ requirements and cross-reference system compatibility before beginning installation. \u003cstrong\u003eDocumentation:\u003c\/strong\u003e \u003ca href=\"https:\/\/www.vikinggroupinc.com\/sites\/default\/files\/2026-05\/051404_02.pdf\"\u003eDownload Manufacturer Technical Data \u0026amp; Cut Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Fire Protection Parts","offers":[{"title":"E-2 \/ Firecycle III Multi-Cycle Deluge","offer_id":67884691456233,"sku":"28179E-2B","price":9217.99,"currency_code":"USD","in_stock":true},{"title":"D-1B \/ Surefire Single Interlock Preaction","offer_id":67884691489001,"sku":"28231D-1B","price":9236.99,"currency_code":"USD","in_stock":true},{"title":"D-2B \/ Surefire Double Interlock Preaction","offer_id":67884691521769,"sku":"28232D-2B","price":9517.99,"currency_code":"USD","in_stock":true},{"title":"E-3B \/ Firecycle III Multi-Cycle Wet","offer_id":67884691554537,"sku":"28184E-3B","price":8982.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0848\/4002\/2249\/files\/TRIMPAC_13798D_SF_SI.png?v=1793986488","url":"https:\/\/nextgear-2013.myshopify.com\/products\/trimpac%c2%ae-brass-monitored-fire-sprinkler-control-trim-case-assembly","provider":"Next Gear","version":"1.0","type":"link"}